Description
The SolarEdge HD-Wave SE6000H-US is a single-phase, grid-tied PV inverter that delivers 6,000 watts of continuous AC output power at 240 household volts. Capable of receiving 9,300 watts of DC solar input, the 6kW HD-Wave is packed with features including an DC/AC safety switch disconnect, Automatic Rapid Shutdown upon grid outage, built-in module-level monitoring, two independent DC string inputs, and a 12 year warranty. The SolarEdge HD-Wave inverter is designed for distributed DC architecture with superior 99% efficiency; Small, lightweight and easy to mount for outdoor or indoor installation. Get the latest SolarEdge HD-Wave technology for the lowest cost. Order online or PHONE 888-498-3331
Parts / Specifications
Manufacturer: |
SolarEdge Technologies |
Model: |
SE6000H-US |
OUTPUT AC: |
____ |
Rated AC Output Power: |
6,000 watts |
Maximum AC Output Power: |
6,000 watts |
AC Output Voltage Nominal: |
240 Volts |
AC Output Voltage Min - Max: |
211 to 264 Volts |
Maximum Continuous Output Current: |
25.0A @ 240V |
GFDI Threshold: |
1 Amp |
INPUT DC: |
____ |
Maximum DC Power (STC): |
9,300 watts |
Maximum DC Input Voltage: |
480V |
Nominal DC Input Voltage: |
380V |
Maximum Input Current: |
16.5 Amps |
Maximum Input Short Circuit Current: |
45 |
Maximum Inverter Efficiency: |
99.2% |
CEC Weighted Efficiency: |
99%% |
Ground-Fault Isolation Detection: |
600k Sensitivity |
Nighttime Power Consumption: |
2.5 watts |
Transformer-less, Ungrounded: |
____ |
Reverse-Polarity Protection: |
____ |
FEATURES: |
____ |
Automatic Rapid Shutdown upon AC Grid Disconnect per NEC 2014 690.12: |
____ |
Arc fault protection for NEC 2011 690.11: |
____ |
Utility Monitoring, Islanding Protection: |
____ |
Supported Communication Interfaces: |
RS485, Ethernet, ZigBee (optional), Cellular (optional) |
Revenue Grade Data, ANSI C12.20: |
Optional (Revenue grade inverter P/N: SExxxxH-US000NNC2) |
OPTIONAL: |
Self-sustaining GFDI power outlet, 120V, 1,500 watts |
COMPLIANCE: |
____ |
Safety: |
UL1741, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 |
Grid Connection Standards: |
IEEE1547, Rule 21, Rule14 (HI) |
Emissions: |
FCC Part 15 Class B |
INSTALLATION SPECSIFICATIONS: |
____ |
AC Output Conduit Size: |
3/4 minimum |
DC Input Conduit Size: |
3/4 minimum |
DC Input Strings: |
1 or 2 |
Dimensions: |
17.7 x 14.6" x 6.8" (450mm x 370mm x 174mm)" |
Weight with disconnect: |
25.3 lbs (11.5 kg) |
Noise: |
25 dBA |
Cooling: |
Natural Convection |
Enclosure Protection rating: |
NEMA 3R, indoor/outdoor |