null

5kW Grid Tied Inverter SolarEdge HD Wave 1-Ph

(No reviews yet) Write a Review
SKU:
SE5000H
MPN:
SE5000H
Availability:
SHIPS 1 - 2 WEEKS
Shipping:
$150.00 (Fixed Shipping Cost)
$2,100.00

Description

The SolarEdge HD-Wave SE5000H-US is a single-phase, grid-tied PV inverter that delivers 5,000 watts of continuous AC output power at 240 household volts. Capable of handling 7,750 watts of DC solar input, the 5kW HD-Wave is packed with features including an DC/AC safety switch disconnect, Automatic Rapid Shutdown upon grid outage, built-in module-level monitoring, two independent DC string inputs, and a 12 year warranty. The SolarEdge HD-Wave inverter is designed for distributed DC architecture with superior 99% efficiency; Small, lightweight and easy to mount for outdoor or indoor installation. Get the latest SolarEdge HD-Wave technology for the lowest cost. Order online or PHONE 888-498-3331


WANT A SOLAR PANEL SYSTEM AT THE LOWEST COST? START SOLAR DESIGN
View AllClose

Parts / Specifications

Manufacturer:
SolarEdge Technologies
Model:
SE5000H-US, US000BEU4, US000BNU4
OUTPUT AC:
____
Rated AC Output Power:
5.000 watts
Maximum AC Output Power:
5,000 watts
AC Output Voltage Nominal:
208 or 240 Volts
AC Output Voltage Min - Max:
183 - 229 @ 208V
AC Output Voltage Min - Max:
211 - 264 @ 240V
Maximum Continuous Output Current:
21A @ 240V; 24A @ 208V
Operating Frequency:
59.3 - 60.5 Hz
GFDI Threshold:
1 Amp
INPUT DC:
____
Maximum DC Power (STC):
7,750 watts
Maximum DC Input Voltage:
480V
Nominal DC Input Voltage:
380V
Maximum Input Current @ 208V:
15.5 Amps
Maximum Input Current @ 240V:
13.5 Amps
Maximum Input Short Circuit Current:
45
Maximum Inverter Efficiency:
99.2%
CEC Weighted Efficiency:
99%
Ground-Fault Isolation Detection:
600k Sensitivity
Nighttime Power Consumption:
2.5 watts
Transformer-less, Ungrounded:
____
Reverse-Polarity Protection:
____
FEATURES:
____
Automatic Rapid Shutdown upon AC Grid Disconnect per NEC 2014 690.12:
____
Arc fault protection for NEC 2011 690.11:
____
Utility Monitoring, Islanding Protection:
____
Supported Communication Interfaces:
RS485, Ethernet, ZigBee (optional), Cellular (optional)
Revenue Grade Data, ANSI C12.20:
Optional (Revenue grade inverter P/N: SExxxxH-US000NNC2)
OPTIONAL:
Self-sustaining GFDI power outlet, 120V, 1,500 watts
COMPLIANCE:
____
Safety:
UL1741, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07
Grid Connection Standards:
IEEE1547, Rule 21, Rule14 (HI)
Emissions:
FCC Part 15 Class B
INSTALLATION SPECSIFICATIONS:
____
AC Output Conduit Size: 3/4 minimum:
14 to 6 AWG"
DC Input Conduit Size: 3/4 minimum:
14 to 6 AWG"
DC Input Strings:
1 or 2
Dimensions:
17.7 x 14.6" x 6.8" (450mm x 370mm x 174mm"
Weight with disconnect:
25.3 lbs (11.5 kg)
Noise:
25 dBA
Cooling:
Natural Convection
Operating Temperature range:
-13F to +140F (-25C to 60C)
Enclosure Protection rating:
NEMA 3R, indoor/outdoor
View AllClose

0 Reviews