The EG4 12kW hybrid inverter charger is a plug and play install and high performing 12,000 watt (12kW) output, 50A at 240Vac, continuous power system for grid-tied or stand-alone solar power generation. The EG4 18KPV-12LV is perfect for homes, light commercial or backup power systems. The single unit operates as a power inverter, battery charger, connection unit, and system monitor that will minimize utility grid dependence and optimize the balance between battery storage and renewable energy sources. This EG4 hybrid inverter eliminates the need for charge controllers or transformers to create a convenient, independent, all-purpose power system. The inverter is capable of 200A AC Bypass for use with solar, battery and generator power, and can  can be connected to up to 21,000 DC watts of solar panels. The user-friendly interface with an LCD display offers user-configurable and easy-accessible button operation, including battery charging current, AC/Solar charger priority, and acceptable input voltage based on different applications. Backed by a 10 year product warranty.


WANT A SOLAR PANEL SYSTEM AT THE LOWEST COST? START SOLAR DESIGN


FEATURES

  • 18,000 Watt DC PV input
  • 12,000 Watt continuous AC output at 240Vac
  • 200 Amp AC Bypass for use with solar, battery and generator
  • Stackable - Parallel multiple units together
  • Closed loop communication with EG4 batteries
  • Overload, short circuit & over temperature protection
  • Line balancing
  • Fully outdoor rated (Avoid direct sunlight)
  • Approved for UL 1741SB Rule 21, Hawaii Rule 14H, California Rule 21 Phase I, II, III
View AllClose

Parts / Specifications

Manufacturer:
EG4 Electronics
Model:
EG4-18KPV-12LV
Solar AC Input Data:
SOLAR AC INPUT DATA
Nominal AC Voltage:
240 / 208VAC
Frequency:
50/60Hz
Max. Continuous AC Current:
50A
Solar AC Grid Output Data:
SOLAR AC GRID OUTPUT DATA
Max. Continuous Output Current:
50A
AC Bypass (Grid):
200A
Rated Voltage:
240VAC
Operating Voltage Range:
180–270VAC
Nominal Power Output (W):
@240V 12kW/@208V 10.4kW
Operating Frequency:
50/60Hz
Phase Shift:
0.99 at full load
Reactive Power Adjust Range:
(-0.8) – (+0.8) leading adjustable
Sync Inrush Current:
35A
Backup/UPS AC Output Data:
BACKUP/UPS AC OUTPUT DATA
Rated Output Current (240V/208V):
50A
AC Bypass (Generator):
90A
DC Input Voltage Range:
100V-600V (550V Max Recommended)
Nominal DC Input Voltage:
360V
Full Power MPPT Voltage Range:
230V-500V
Max. DC Input Current:
25A/15A/15A
Number of MPPT:
3(2/1/1)
OUTPUT/INPUT AC (Grid):
AC POWER
Nominal Output Voltage:
120/240 VAC, 120/208 VAC
Nominal AC Frequency:
50Hz/60Hz
Nominal Output Current:
50A @ 240V
Rated Output Power (W):
@240VAC 12kW/@208VAC 10.4kW
Max Cont. Line Wattage:
8kW per 120V
Peak Power (W):
With PV: 14.7kW (10 min), 15.5kW (5 min) Without PV: 13.5kW (10 min)
Switching Time:
<20 ms
Battery Parameters:
BATTERY PARAMETERS
Compatible Battery Type:
Lead-acid battery/Lithium battery
Nominal Battery Voltage:
48V
Battery Voltage Range:
40V-60V
Maximum Charging/Discharging Current:
250A
Battery Nominal Voltage:
48 VDC
Battery Voltage Range:
40-60 VDC
MPPT Efficiency:
99.9%
Max. Efficiency:
97.5%
Battery Charging Efficiency:
95%
Integrated Disconnect:
DC switch
Anti-islanding Protection:
YES
DC Switch:
YES
SPD Protection:
YES
AFCI:
YES
Rapid Shut Down (RSD):
YES
General Data:
GENERAL DATA
Dimensions:
34.2 x 20.5 x 11.2 in (870 x 520 x 285 mm)
Weight:
121.25 lbs (55 kg), 132.28 lbs (60kg) with the packaging
Display:
Color Touch LCD
Operating Temperature Range:
-13 to 140 ° F ( -25 to 60 °C)
Cooling:
Fan
Communication:
RS485/Wi-Fi/CAN
Warranty:
10 year standard warranty
Certifications:
UL1741SB Rule 21, Rapid Shut Down (RSD) NEC 2020:690.12, IEEE 1547.1:2020; IEEE 1547:2018, Hawaii Rule 14H, California Rule 21 Phase I, II, III